Rayence XR5

Enhance both staff workflow and the patient experience with auto tracking of the vertical wall stand and table Bucky detector movements

Description

Compact and scalable, the XR5 is well suited for all exam types and imaging environments, especially orthopedics, imaging centers, and urgent care centers and is compatible with all Rayence detectors. Enhance both staff workflow and the patient experience with auto tracking of the vertical wallstand and table Bucky detector movements. Requiring no special ceiling or electrical preparation, the XR5 can be installed in rooms just 13 feet wide by 13 feet deep by 8 feet high and 2-8-240VAC line voltage.

Features

40kW generator with 200 kHU X-ray tube and manual collimator

Full Console APR to X-ray generator integration with two-way communication

4-wayfloating tabletop (550 lb. weight capacity; 32 x 90 in. tabletop dimensions)

16in. minimum floor-to-focus height (58 in. total tube head travel)

Rayence14x17 Cesium Iodide wireless detector and Xmaru image acquisition software

One-yearX-ray system warranty (Three-year wireless detector warranty)

The XR5 is compatible with all Rayence detectors and advanced Xmaru Image Acquisition software.

Specifications

Generator     Power Output              40kW

                     kV Range                      40-125kV

                     mA Range                     10-500mA

                     Input Phase / Voltage  1Ф / 208-2300Vac

                     Exposure Time Range   6.3s Max.

Tube             Focal Spot Value           0.6 – 1.5 mm

                    Target Angle                 16°

                    Target Diameter            74mm

                    Anode Heat Content    200 kHU

                    Cooling Method            Natural / Forced Air

Collimator    Type                              Manual

                    Power Output               DC 24V

                    Projection Lamp           150W Halogen Lamp

                    Lamp Timer                    Push Button, 30 seconds

                    Rotation Angle               -10 ˚ ~ 180 ˚ as minimum

                    APR Memory                  No

                    Laser Guide                   No

                    Max. Window                18.9 x 18.9 in (SID 40 in)

                   Min. Window Time          2 x 2 in (SID 40 in)

Floor Mounted    Power Required           24V, 3A

Tube Stand         Tube Stand                   1,940 mm

                           SID Range                     40 in ~ 72 in

                           Vertical Travel              58 in

                           Longitudinal Travel      100 in

                           Tube Rotation Range    -135˚ ~ +135˚

                           Tube Arm IN / OUT        4.7 in

4 Way Table         Dimensions                  90 in (l) x 32 in (w) x 26 in (h)

                           Forward-Backward Movement      ± 4.2 in

                           Left-Right Movement                   ± 11.2 in

                           Table Cabinet Movement              ± 347mm (±10)

                           Load Capacity                               550 lbs.

6 Way Table         Load Capacity                               660 lbs.

                           Max lift capacity                           550 lbs.