Konica Minolta DR Panels
.
AeroDR 1417HQ
PRODUCT CODE: 1417HQ
World’s Lightest Weight (including battery) (2.9kg) This 14″x17″ Cesium Iodide detector is easy to handle making it especially convenient for multi-room use.
Scintillator Direct-Contact Technology
Konica Minolta succeeded by creating a new technology whereby a CsI scintillator is made to contact directly over a TFT*1 sensor panel without any protective layer in between them. This technology has made it possible to guide the light emitted from the scintillator to the photodiode without causing the light to be dispersed at the interface with the TFT sensor.
- Scintillator Cesium Iodide (CsI)
- High Image Quality with spatial resolution of 175 μm Limiting resolution:3.5 lp/mm
- Pixel matrix: 1996 x 2434
- Wide active area of 13.7″ x 16.7″
- Wired dedicated communication or Wireless transfer of data
- Dimensions:15.1″ x 18.1″ x 0.63″ Weight: 6.4 lbs. w/battery
- Bit depth (A/D):16 bit A/D
- Image display:< 4 sec. Cycle time:8-12 sec.
- 1 Year Warranty
Multimedia:
.
AeroDR 1012HQ
PRODUCT CODE: 1012HQ
The lightest FPD in the world (as of 2013) , weighs only 1.7Kg including batteries. It is an ideal solution for exams such as pediatric or extremities.
Scintillator Direct-Contact Technology
Konica Minolta succeeded by creating a new technology whereby a CsI scintillator is made to contact directly over a TFT*1 sensor panel without any protective layer in between them. This technology has made it possible to guide the light emitted from the scintillator to the photodiode without causing the light to be dispersed at the interface with the TFT sensor.
- Scintillator Cesium Iodide (CsI)
- High Image Quality with spatial resolution of 175 μm Limiting resolution:3.5 lp/mm
- Pixel matrix: 1404 x 1696
- Wide active area of 9.7″ x 11.7″
- Wired dedicated communication or Wireless transfer of data
- Dimensions:11.1″ x 13.1″ x 0.63″ Weight: 3.75 lbs. w/battery
- Bit depth (A/D):16 bit A/D
- Image display:< 4 sec. Cycle time:7-9 sec.
- 1 Year Warranty
Multimedia:
.
AeroDR 1717HQ
PRODUCT CODE: 1717HQ
The most lightweight (3.6Kg) 17”x17” panel, despite being cassette size and wireless. The larger image area allows more anatomy to be imaged, thereby reducing positioning errors.
Scintillator Direct-Contact Technology
Konica Minolta succeeded by creating a new technology whereby a CsI scintillator is made to contact directly over a TFT*1 sensor panel without any protective layer in between them. This technology has made it possible to guide the light emitted from the scintillator to the photodiode without causing the light to be dispersed at the interface with the TFT sensor.
- Scintillator Cesium Iodide (CsI)
- High Image Quality with spatial resolution of 175 μm Limiting resolution:3.5 lp/mm
- Pixel matrix: 2428 x 2428
- Wide active area of 16.7″ x 16.7″
- Wired dedicated communication or Wireless transfer of data
- Dimensions:18.1″ x 18.1″ x 0.63″ Weight: 7.9 lbs. w/battery
- Bit depth (A/D):16 bit A/D
- Image display:< 4 sec. Cycle time:8-14 sec.
- 1 Year Warranty
Multimedia:
.
Konica Minolta Direct Radiography Acquisition Workstation
The AeroDR System combines the CS-7 console and highly durable Aero DR detectors to deliver unique solutions that increase economic value through high uptime and increased productivity. With superb image quality, advanced imaging tools and greater dose efficiency, the AeroDR System enhances clinical confidence and patient satisfaction.
PRODUCT CODE: CS-7
CS-7 Features
Send patient images to PACS
Obtain examination information from RIS and send back each results.
Link up X-ray exposure condition with X-ray console
Write patient image on CD/DVD with DICOM,
PDI and JPEG format
Quick image preview in under 2 seconds
User-friendly graphical user interface (GUI) adding new and powerful proprietary functions
Easily modify GUI to meet customer preferences and flexibility needs
Intelligent Grid Function improves contrast which is affected by scattered radiation without a grid. This provides easy workflow, and does not require the operator to carry the grid to perform an exam
Highlight Function can highlight tube /gauze in images that are difficult to be detected in normal images
Multimedia:
.
Konica Minolta Image Stitching
PRODUCT CODE: CS7-IS
Stitching Function can combine 2 or 3 images and also can adjust combined position of images on the screen. This function is useful at handling long image as 1 image.
Delworks Quality Control Phantom
PRODUCT CODE: DRQC
The DR QC Phantom allows comprehensive quality assurance testing for DR Detectors and associated software. The phantom enables seven quality assurance assessments for monthly and semi-annual evaluation, including exposure linearity and sensitivity, high and low contrast reproducibility, artifact and residual image detection, image resolution, collimator beam alignment, measurement tool accuracy, and display jitter QA testing.